Gas Fired Hot Water Steam Boiler / Industrial Water Tube Boiler Single Drum
Product Details
| Product Name: | Biomass Hot Water Boiler | Function: | Steam Boiler , Hot Water Boiler |
|---|---|---|---|
| Structure: | Water Tube | Usage: | Industrial |
| Applicable Fuel: | Bituminous Class II | Port: | Shanghai , China |
| Highlight |
industrial steam boiler,coal fired hot water boiler |
||
Product Description
Introduction
HD BOILER DZL series steam and hot-water boiler is the single-cylinder, water-tube assembly, chain grate boiler. Boiler drum is arranged along the center of the boiler longitudinally.Coal economizer is installed at the Rear of boiler. Fume is absorbed by the hearth, the fume flows to the convection heating surface.Through cooling chamber and exhausts outside through the chimney via coal.Economizer, dust collector and draught fan.
Structural features
1. Horizontal single drum water pipe chain grate boiler. Is composed of the upper body and lower grate boiler.
2. Longitudinal layout for single drum boiler body, boiler drum with two side water wall tube of the chamber radiation heating surface, regardless of the convective heating surface on both sides of the pipe bundle.
3. Drum internal thread smoke convection heating surface pipe fire tube, tube sheet with low stress without braced arch tube plate.
4. Chain grate points warehouse into the wind, the wind chamber air volume adjustment independently, grate stepless speed regulation.
Performance advantages
1. Boiler for group(fast)form, compact structure, cover an area of an area small, short installation period, less installation cost, infrastructure investment.
2. The tube plate in smoke temperature is low, single return pipe, tube plate heated evenly, tube plate stress low boiler operation safe and reliable, long service life.
3. The arrangement of heating surface, the reasonable fully, boiler heating, pressure rise faster, output full, high thermal efficiency.
4. Grate points warehouse into the wind, the wind room independent adjust air flow, coal bruning evenly, wide adaptability of coal.
5. Safety a high degree of automation, automatic control and monitoring instrument is complete, safe and reliable, easy operation.
Product parameters
| Steam Boiler Model | DZL1-0.7-AII DZL1-1.0-AII |
DZL2-1.25-AII DZL2-1.6-AII DZL2-2.5-AII |
DZL4-1.25-AII DZL4-1.6-AII DZL4-2.5-AII |
DZL6-1.25-AII DZL6-1.6-AII DZL6-2.5-AII |
DZL10-1.25-AII DZL10-1.6-AII |
DZL15-1.25-AII DZL15-1.6-AII |
DZL20-1.25-AII DZL20-1.6-AII |
|
| Rated evaporation capacity(t/h) | 1 | 2 | 4 | 6 | 10 | 15 | 20 | |
| Rated working pressure(MPa) | 0.7/1.0 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | 1.25/1.6 | |
| Rated steam temperture(℃) | 170/184 | 193/204/226 | 193/204/226 | 193/204 | 193/204 | 193/204 | 193/204 | |
| Water-supply temperature(℃) | 20 | 20 | 20 | 20 | 20 | 20 | 20 | |
| Area of grate (m2) | 3.5/20/10 | 6.5/40/17 | 11/88/17 | 16/118/50 | 17/200/131 | 35/332/200 | 53/415/213 | |
| Effective area of grate (m2) | 2.1 | 3.2 | 5.2 | 7.8 | 11.8 | 17.3 | 21 | |
| Boiler volume (m3) | 3.6 | 6.5 | 9.2 | 12.3 | 16.5 | 20 | 25 | |
| Design efficiency (%) | >76 | >78 | >78 | >80 | >80 | >80 | >80 | |
| Applicable fuel | Bituminous class II | |||||||
| Fuel consumption(kg/h) | 167.9 | 330 | 655 | 870 | 1440 | 2240 | 2860 | |
| Maximum size of shipping part (m) | 5.5×1.8×2.9 | 5.7×2.6×3.4 | 6.8×2.9×3.6 | 7.1×2.8×3.6 | 7.6×3.4×3.6 | 9.4×3.4×3.6 | 9.8×3.5×3.6 | |
| Maximum weight of shipping part (t) | 13 | 17 | 28 | 22 | 25 | 26 | 27 | |
| Size of installation (m) | 6.0×3.2×4.2 | 5.7×3.9×4.9 | 6.8×3.6×5.1 | 8.1×5.2×6.3 | 9.8×5.7×6.3 | 10.4×5.2×8.1 | 11×5.6×8.6 | |
| Draught fan | model | Y5-47 | GY2-15 | YX9-35No.8C | GY6-1 | GY10-15 | Y5-47 12D | Y5-47 12.4D |
| airflow(m3/h) | 3295-5100 | 5200-8500 | 8868-19342 | 14000-20000 | 26321-32138 | 33318-50356 | 36762-55561 | |
| pressure(Pa) | 2383-2079 | 3668-3020 | 2805-3041 | 3060-3220 | 3714-3802 | 3628-3393 | 3874-3619 | |
| power(kw) | 5.5 | 11 | 18.5 | 30 | 55 | 75 | 90 | |
| Blower fan | model | T4-72 3A | GG2-11 | T4-72 4.5A | T4-72 5A | GG10-1 | G4-73 9D | G4-73 9D |
| airflow(m3/h) | 1688-3517 | 3189-4130 | 5360-10288 | 7352-10249 | 1000-22500 | 23003-32079 | 23003-44128 | |
| pressure(Pa) | 792-1300 | 1578-1461 | 2582-1616 | 3195-2954 | 2690-1620 | 2668-2559 | 2668-1775 | |
| power(kw) | 1.5 | 3 | 7.5 | 11 | 15 | 30 | 37 | |
| Feed pump | model | JGGC2.0-8×14/18 | JGGC2.4-9×19/22 DG6-25×11 |
DG6-25×7/8 DG6-25×12 |
DG6-25×7/9 DG6-25×12 |
DG12-25×7/8 | DG25-30×6/7 | DG25-30×6/7 |
| airflow(m3/h) | 2.4 | 2.4/2.4/3.75 | 3.75-7.5 | 3.75-7.5 | 7.5-15 | 15-30 | 15-30 | |
| Lift(m3/h) | 119/153 | 152/176/280 | 175/200/300 | 175/225/300 | 175/200 | 180/210 | 180/210 | |
| power(kw) | 3 | 3 | 7.5/11/15 | 7.5/15/15 | 15/15 | 30/30 | 30/30 | |
| Speed govemor | model | GL-5P | GL-5P | GL-5P | GL-10P | GL-16P | GL-20P/II | GL-20P/II |
| power(kw) | 0.55 | 0.55 | 0.55 | 0.75 | 1.1 | 1.5 | 1.5 | |
| Slag machine | model | LXL-1 | LXL-2 | LXL-4 | LXL-6 | LXL-10 | LXL-15 | LXL-20 |
| power(kw) | 0.75 | 1.1 | 1.1 | 1.1 | 1.1 | 1.5 | 1.5 | |
| Dust model | XD-1 | XD-2 | XD-4 | XD-6 | XD-10 | XD-15 | XD-20 | |
| Hot Water Boiler Model | DZL0.7-0.7/95/70-ALL |
DZL1.4-0.7/95/70-ALL DZL1.4-1.0/115/70-ALL |
DZL2.8-0.7/95/70-ALL DZL2.8-1.0/115/70-ALL |
DZL4.2-0.7/95/70-ALL DZL4.2-1.0/115/70-ALL |
DZL7-1.0/95/70-ALL DZL7-1.0/115/70-ALL |
DZL10.5-1.0/95/70-ALL DZL10.5-1.0/115/70-ALL |
DZL14-1.0/95/70-ALL DZL14-1.25/130/70-ALL |
|
| Rated Heating Power(MW) | 0.7 | 1.4 | 2.8 | 4.2 | 7 | 10.5 | 14 | |
| Rated working pressure(MPa) | 0.7 | 0.7/1.0 | 0.7/1.0 | 0.7/1.0 | 1.0 | 1.0 | 1.0/1.25 | |
| Rated outlet temperture(℃) | 95 | 95/115 | 95/115 | 95/115 | 95/115 | 95/115 | 115/130 | |
| Rated inlet temperture(℃) | 70 | 70 | 70 | 70 | 70 | 70 | 70 | |
| Boiler volume (m3) | 3.6 | 6.5 | 9.2 | 12.3 | 16.5 | 20 | 25 | |
| Design efficiency (%) | >76 | >78 | >79 | >81 | >81 | >81 | >81 | |
| Applicable fuel | Bituminous class II | |||||||
|
Fuel consumption(kg/h) |
162.4 | 327.1 | 654.2 | 981.3 | 1594.7 | 2392.0 | 3189.3 | |
| Maximum size of shipping part (m) | 6.0×4.2×4.2 | 6.5×4.5×4.8 | 7.2×4.1×4.9 | 9.5×5.5×6.3 | 9.8×5.7×6.3 | 9.4×3.4×3.6 | 9.8×3.5×3.6 | |
| Maximum weight of shipping part (t) | 13 | 21 | 27 | 25 | 33 | 42 | 49 | |
| Size of installation (m) | 6.0×4.2×4.2 | 6.5×4.5×4.8 | 7.2×4.1×4.9 | 9.5×5.5×6.3 | 9.8×5.7×6.3 | 10.7×5.7×6.8 | 11×5.8×8.6 | |
| Draught fan | model | GY1-11 | GY2-15 | YX9-35No.8C | GY6-1 | GY10-15 | Y5-47 12D | Y5-47 12.4D |
| airflow(m3/h) | 3295-5100 | 5200-8500 | 8868-19342 | 14000-20000 | 26321-32138 | 33318-50356 | 36762-55561 | |
| pressure(Pa) | 2383-2079 | 3668-3020 | 2805-3041 | 3060-3220 | 3714-3802 | 3628-3393 | 3874-3619 | |
| power(kw) | 5.5 | 11 | 18.5 | 30 | 55 | 75 | 90 | |
| Blower fan | model | T4-72 3A | GG2-11 | T4-72 4.5A | T4-72 5A | GG10-1 | G4-73 9D | G4-73 9D |
| airflow(m3/h) | 1688-3517 | 3189-4130 | 5360-10288 | 7352-10249 | 1000-22500 | 23003-32079 | 23003-44128 | |
| pressure(Pa) | 792-1300 | 1578-1461 | 2582-1616 | 3195-2954 | 2690-1620 | 2668-2559 | 2668-1775 | |
| power(kw) | 2.2 | 3 | 7.5 | 11 | 15 | 30 | 37 | |
| Blower fan | model | 4-72-3.2 | GG2-11 | T4-72 4.5 | T4-72 5 | GG10-1 | G4-73 9D | G4-73 9D |
| (m3/h) | 1688-3517 | 3189-4130 | 5360-10288 | 7352-10249 | 10000-22500 | 23003-32079 | 23003-44128 | |
| airflow(m3/h) | 119/153 | 152/176/280 | 175/200/300 | 175/225/300 | 175/200 | 180/210 | 180/210 | |
| power(kw) | 3 | 3 | 7.5/11/15 | 7.5/15/15 | 15/15 | 30/30 | 30/30 | |
| Speed governor | model | GL-5P | GL-5P | GL-5P | GL-10P | GL-16P | GL-20P/II | GL-20P/II |
| power(kw) | 0.55 | 0.55 | 0.55 | 0.75 | 1.1 | 1.5 | 1.5 | |
| Slag machine | model | LXL-1 | LXL-2 | LXL-4 | LXL-6 | LXL-10 | LXL-15 | LXL-20 |
| power(kw) | 0.75 | 1.1 | 1.1 | 1.1 | 1.1 | 1.5 | 1.5 | |
| Dust model | XD-1 | XD-2 | XD-4 | XD-6 | XD-10 | XD-15 | XD-20 | |
Company Introduction
Established in 1985,Zhangjiagang Hua Dong Boiler Co.,Ltd.(trading as HD Boiler),produces power plant; industrial; waste heat; waste incineration; biomass; organic heat carrier and electric steam boilers. Coupled with a comprehensive range of heating surfaces, HD Boiler brings to the market a unique service including boiler design , fabrication, installation, maintenance and replacement of boiler pressure parts.
1. Fabrication area of 200,000 square meters
2. 150 Engineers
3. 600 Coded welders
4. 60 Licensed Inspectors(NDT Level-III instructors)
5. Class-A Licenses for Design and Manufacture Boiler
6. ISO 9001:2008 Quality System
7. ASME Certificate of Power Boilers
8. ASME 'S','U' and NB stamp authorization

Product Highlights
Introduction HD BOILER DZL series steam and hot-water boiler is the single-cylinder, water-tube assembly, chain grate boiler. Boiler drum is arranged along the center of the boiler longitudinally.Coal economizer is installed at the Rear of boiler. Fume is absorbed by the hearth, the fume flows to ...
High Pressure Power Boiler Heating Surface Membrane Wall Argon Arc Welding For Biomass Boiler
High Pressure Power Boiler Heating Surface Membrane Wall Argon Arc Welding For Biomass Boiler Product Introduction Water wall panels with pins usually laid vertically on the inner wall of the furnace wall, it is mainly used to absorb the radiant heat emitted by the flame and high-temperature flue gas in the furnace.It is the main type of evaporating heating surface of all kinds of modern boilers and the basic component of boiler water circulation loop.Because of both cooling
High Frequency Welding H Fin Tube Economizer For Power Plant Boiler ASME
High Frequency Welding H Fin Tube Economizer For Power Plant Boiler ASME Product Description The boiler economizer is a device used to recover waste heat in industrial boilers, usually located at the tail of the flue of the boiler, which increases the feed water temperature and reduces fuel consumption by absorbing the heat of the flue gas, so as to achieve the effect of energy saving and emission reduction. But at the same time, as an environmental protection equipment, the
Carbon Steel SA192 Superheater Coil Argon Arc Welding 100% PT
Product Description: A boiler superheater is an essential component in a boiler system, responsible for increasing the temperature of steam produced by the boiler. One of the key products in this category is the Superheater Coil, designed to enhance the efficiency and performance of boiler systems. This particular superheater is suitable for various fuels, including coal, oil, and biomass, making it versatile and adaptable to different energy sources. The Superheater Coil
Boiler Industrial SA210A1 Steel Boiler Economizer Heat Exchange Part ASME Certification
Boiler Industrial SA210A1 Steel Boiler Economizer Heat Exchange Part ASME Certification Introduction The H-shaped finned tube is also known as the H-shaped fin tube, also known as the butterfly fin tube. It is to weld symmetrically two pieces of steel with an arc in the middle to form fins (ribs or butterflies), the frontal shape of which resembles the letter "H", so it is called the H-shaped finned tube. The two fins of the H-shaped fin tube are rectangular and approximately
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.