Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations

MOQ: 1
Price: US$4,590
Detail Information
Place of Origin
Jiangsu, China
Brand Name
HDB
Type:
Natural Circulation
Structure:
Water Tube
Pressure:
High Pressure
Steam Production:
Max. 20t/h
Style:
Horizontal
Output:
Hot Water
Material:
Carbon Steel, Alloy Steel, ND Steel
Weight:
1-20 Ton
Fuel:
Coal-fired
Diameter (OD):
76mm~914mm
Max Length:
23000mm
Temperature:
300~1500℃
Packing:
Iron Frame
Core Components Warranty:
5 Years
Boiler Type:
CFB Boiler
Highlight:

1-20 Ton Weight Boiler Manifold Headers

,

Industrial Boiler Manifold Headers

,

Water Tube Boiler Manifold Headers

Product Description
Carbon Steel Manifold Boiler Headers for Power Station
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 0 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 1
Headers collect and distribute steam or water from or to a series of smaller pipes or conduits. Manufactured from carbon or ferritic steel, they typically match the grade of the connected piping systems. Unlike piping systems that are usually butt-welded and bent, headers maintain a straight configuration.
The operational pressures and temperatures headers must withstand vary based on their connection points. Headers connected to economizers or water wall panels face less demanding material requirements than those connected to superheaters or reheaters.
Vallourec supplies header tubes in materials ranging from carbon steel to high-alloy ferritic steels like T/P91 or T/P92, with diameters from 88.9 mm to 406.4 mm, suitable for various temperature and pressure conditions.
Applications
Steam boiler pressure part headers with large-diameter longitudinal welded pipes serve multiple functions including water wall headers, superheater headers, and economizer headers. These components collect, mix, and redistribute working medium. Structurally, they are classified as end cover type (end enclosure) or necking down type.
Technical Specifications
Parameter Range
Diameter (OD) Ø76mm~Ø914mm
Length (Max) 23000mm
Temperature 300~1500°C
Related Products
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 2 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 3
Company Profile
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 4 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 5
Certifications
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 6 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 7
Frequently Asked Questions
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 8 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 9
Contact Information
Address: No.1 Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China
Phone: +86 (0) 512 5866 6196
Fax: +86(0) 512 5877 4453
Website: www.boilerfabrication.com
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 10 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 11
Products
PRODUCTS DETAILS
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations
MOQ: 1
Price: US$4,590
Detail Information
Place of Origin
Jiangsu, China
Brand Name
HDB
Type:
Natural Circulation
Structure:
Water Tube
Pressure:
High Pressure
Steam Production:
Max. 20t/h
Style:
Horizontal
Output:
Hot Water
Material:
Carbon Steel, Alloy Steel, ND Steel
Weight:
1-20 Ton
Fuel:
Coal-fired
Diameter (OD):
76mm~914mm
Max Length:
23000mm
Temperature:
300~1500℃
Packing:
Iron Frame
Core Components Warranty:
5 Years
Boiler Type:
CFB Boiler
Minimum Order Quantity:
1
Price:
US$4,590
Highlight

1-20 Ton Weight Boiler Manifold Headers

,

Industrial Boiler Manifold Headers

,

Water Tube Boiler Manifold Headers

Product Description
Carbon Steel Manifold Boiler Headers for Power Station
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 0 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 1
Headers collect and distribute steam or water from or to a series of smaller pipes or conduits. Manufactured from carbon or ferritic steel, they typically match the grade of the connected piping systems. Unlike piping systems that are usually butt-welded and bent, headers maintain a straight configuration.
The operational pressures and temperatures headers must withstand vary based on their connection points. Headers connected to economizers or water wall panels face less demanding material requirements than those connected to superheaters or reheaters.
Vallourec supplies header tubes in materials ranging from carbon steel to high-alloy ferritic steels like T/P91 or T/P92, with diameters from 88.9 mm to 406.4 mm, suitable for various temperature and pressure conditions.
Applications
Steam boiler pressure part headers with large-diameter longitudinal welded pipes serve multiple functions including water wall headers, superheater headers, and economizer headers. These components collect, mix, and redistribute working medium. Structurally, they are classified as end cover type (end enclosure) or necking down type.
Technical Specifications
Parameter Range
Diameter (OD) Ø76mm~Ø914mm
Length (Max) 23000mm
Temperature 300~1500°C
Related Products
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 2 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 3
Company Profile
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 4 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 5
Certifications
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 6 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 7
Frequently Asked Questions
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 8 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 9
Contact Information
Address: No.1 Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China
Phone: +86 (0) 512 5866 6196
Fax: +86(0) 512 5877 4453
Website: www.boilerfabrication.com
Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 10 Industrial Water Tube Boiler Manifold Headers with 1-20 Ton Weight for Power Stations 11
Sitemap |  Privacy Policy | China Good Quality Superheater Coil Supplier. Copyright © 2017-2025 Zhangjiagang HuaDong Boiler Co., Ltd. . All Rights Reserved.