logo
products
PRODUCTS DETAILS
Home > Products >
Boiler Primary Superheater Reheater Economiser In Steam Power Plant

Boiler Primary Superheater Reheater Economiser In Steam Power Plant

MOQ: 100 pcs
Price: 2,000 - 5,000 USD per pc
Standard Packaging: Sea worthy Packing for Exporting with Iron Frame
Delivery Period: Within 90 Days after getting the down payment or L/C
Payment Method: T/T, L/C at sight
Supply Capacity: About 1,000 tons per month
Detail Information
Place of Origin
China
Brand Name
HD Boiler
Certification
ASME, ISO9001, EN
Model Number
Superheater
Type:
Natural Circulation
Application:
Boiler Maintaince,Boiler Pipe,Heating Element
Material:
Stainless Steel
Usage:
Industrial,Power Station,Thermal Power Plant/station Boiler
Surface Treatment:
Painting, Sandblasting, Galvanizing
Fuel:
Biomass, Waste
Keyword:
Boiler Superheater Tube
Style:
Horizontal And Vertical
Highlight:

Steam Power Plant Superheater Reheater

,

Boiler Superheater Reheater

,

Economiser Superheater Reheater

Product Description

Biomass Waste Heat Rediated Boiler Steam Superheater Serpentuator Stainless Steel​

 

 

How to maintain superheaters and reheaters?


Regular cleaning, temperature monitoring, and using high-quality feedwater help prevent damage.

 

Differences

 

Type Advantages Disadvantages Supporting method
Pendant-type 1.Firm structural support 1. Flow blockage by condensed steam 2. Needs a slow restart to purge the water that accumulates in the bottom. supported from above
Inverted-type 1.Proper drainage of the condensed steam 1. Lack the structural rigidity, especially in high speed gas flow Supported from below
Horizontal -type

1. Proper drainage

2. Good structural rigidity.

1. They do not view the flam directly so they are mainly from the convective type Usually supported in the vertical gas ducts parallel to the main furnace.

Boiler Primary Superheater Reheater Economiser In Steam Power Plant 0

 

 

Principle

 

• Principle of superheater is similar to steam generating tubes of boiler.

The hot gases at high temperature sweep over superheater tubes and raise the temperature of steam which magnitude depends upon exit gas temperature leaving the superheater and gas velocity.

 

Application

 

Use for heating saturated steam, steam temperature could be up to 900 degree C.

Superheater Capacity Upgrades to Increase Power Generation

 

Send us required technical data, such as steam capacity, presure, required temperature etc. We will design accordingly.

Boiler Primary Superheater Reheater Economiser In Steam Power Plant 1
 

products
PRODUCTS DETAILS
Boiler Primary Superheater Reheater Economiser In Steam Power Plant
MOQ: 100 pcs
Price: 2,000 - 5,000 USD per pc
Standard Packaging: Sea worthy Packing for Exporting with Iron Frame
Delivery Period: Within 90 Days after getting the down payment or L/C
Payment Method: T/T, L/C at sight
Supply Capacity: About 1,000 tons per month
Detail Information
Place of Origin
China
Brand Name
HD Boiler
Certification
ASME, ISO9001, EN
Model Number
Superheater
Type:
Natural Circulation
Application:
Boiler Maintaince,Boiler Pipe,Heating Element
Material:
Stainless Steel
Usage:
Industrial,Power Station,Thermal Power Plant/station Boiler
Surface Treatment:
Painting, Sandblasting, Galvanizing
Fuel:
Biomass, Waste
Keyword:
Boiler Superheater Tube
Style:
Horizontal And Vertical
Minimum Order Quantity:
100 pcs
Price:
2,000 - 5,000 USD per pc
Packaging Details:
Sea worthy Packing for Exporting with Iron Frame
Delivery Time:
Within 90 Days after getting the down payment or L/C
Payment Terms:
T/T, L/C at sight
Supply Ability:
About 1,000 tons per month
Highlight

Steam Power Plant Superheater Reheater

,

Boiler Superheater Reheater

,

Economiser Superheater Reheater

Product Description

Biomass Waste Heat Rediated Boiler Steam Superheater Serpentuator Stainless Steel​

 

 

How to maintain superheaters and reheaters?


Regular cleaning, temperature monitoring, and using high-quality feedwater help prevent damage.

 

Differences

 

Type Advantages Disadvantages Supporting method
Pendant-type 1.Firm structural support 1. Flow blockage by condensed steam 2. Needs a slow restart to purge the water that accumulates in the bottom. supported from above
Inverted-type 1.Proper drainage of the condensed steam 1. Lack the structural rigidity, especially in high speed gas flow Supported from below
Horizontal -type

1. Proper drainage

2. Good structural rigidity.

1. They do not view the flam directly so they are mainly from the convective type Usually supported in the vertical gas ducts parallel to the main furnace.

Boiler Primary Superheater Reheater Economiser In Steam Power Plant 0

 

 

Principle

 

• Principle of superheater is similar to steam generating tubes of boiler.

The hot gases at high temperature sweep over superheater tubes and raise the temperature of steam which magnitude depends upon exit gas temperature leaving the superheater and gas velocity.

 

Application

 

Use for heating saturated steam, steam temperature could be up to 900 degree C.

Superheater Capacity Upgrades to Increase Power Generation

 

Send us required technical data, such as steam capacity, presure, required temperature etc. We will design accordingly.

Boiler Primary Superheater Reheater Economiser In Steam Power Plant 1
 

Sitemap |  Privacy Policy | China Good Quality Superheater Coil Supplier. Copyright © 2017-2025 Zhangjiagang HuaDong Boiler Co., Ltd. . All Rights Reserved.