MOQ: | 5 tons |
Standard Packaging: | Sea worthy Packing for Export |
Delivery Period: | 30~50 days |
Customized Durable Carbon Steel Economizer For Waste Heat And Power Boilers
Do gas-fired boilers need special economizer design?
Require enhanced acid dew point protection (condensing design), stainless steel preferred.
Economizer Introduction
A boiler economizer is a heating component in flue ducts that heats feed water to saturated water by absorbing low-temperature flue gas heat, lowering exhaust temperature, saving energy, and improving efficiency. Steel tube types (32–51mm carbon steel, sometimes finned for better heat transfer) have no pressure limits and can be boiling type, primarily recovering boiler waste heat.
Designed to boost boiler efficiency and cut long-term operational costs, economizers preheat water to reduce energy needed for steam generation. While daily savings are small, cumulative impacts are significant. They can be factory-installed or retrofitted as waste heat recovery devices, ensuring unused heat is recycled.
Diameter | 32Φ 38Φ |
Type |
Casting iron economizer;bare tube economizer;finned tube Economizer;spiral finned tube economizer |
Fin height | Less than 17mm |
Fin pitch | 2.1-5mm |
Fin thickness | 3-4mm |
material |
Tube:Carbon steel,alloy steel, customized Fin:copper;Aluminum |
advantages |
1.better product quality and longer service life. 2.energy conservation and environmental protection. 3.significantly improve cycle efficiency. |
The economizer can absorb the heat of high temperature flue gas,reduce the exhaust temperature,save energy,and improve the efficiency of boiler.
Non-standard size please provide these parameter
Boiler economizer(gas liquid heat exchanger)design | ||||
Flue gas inlet(temp.) | Flue gas outlet(temp.) | Liquid inlet(temp.) | Liquid outlet(temp.) | Flue gas flow |
ºC | ºC | ºC | ºC | m3/h |
FAQ
A: The brand name of this product is HD Boiler.
A: The model number of this product is Boiler economizer.
A: This product is made in China.
A: This product is certified by ASME, ISO9001:2015, and ISOEN3834.
A: The minimum order quantity for this product is 3 tons.
A: Yes, the price for this product is negotiable.
A: This product is packaged in iron frames.
A: The delivery time for this product depends on the quantity ordered.
A: The payment terms for this product are 30% after contract and balance 70% before shipment, or 100% L/C at sight.
A: The supply ability for this product is 100 tons per month.
![]() |
MOQ: | 5 tons |
Standard Packaging: | Sea worthy Packing for Export |
Delivery Period: | 30~50 days |
Customized Durable Carbon Steel Economizer For Waste Heat And Power Boilers
Do gas-fired boilers need special economizer design?
Require enhanced acid dew point protection (condensing design), stainless steel preferred.
Economizer Introduction
A boiler economizer is a heating component in flue ducts that heats feed water to saturated water by absorbing low-temperature flue gas heat, lowering exhaust temperature, saving energy, and improving efficiency. Steel tube types (32–51mm carbon steel, sometimes finned for better heat transfer) have no pressure limits and can be boiling type, primarily recovering boiler waste heat.
Designed to boost boiler efficiency and cut long-term operational costs, economizers preheat water to reduce energy needed for steam generation. While daily savings are small, cumulative impacts are significant. They can be factory-installed or retrofitted as waste heat recovery devices, ensuring unused heat is recycled.
Diameter | 32Φ 38Φ |
Type |
Casting iron economizer;bare tube economizer;finned tube Economizer;spiral finned tube economizer |
Fin height | Less than 17mm |
Fin pitch | 2.1-5mm |
Fin thickness | 3-4mm |
material |
Tube:Carbon steel,alloy steel, customized Fin:copper;Aluminum |
advantages |
1.better product quality and longer service life. 2.energy conservation and environmental protection. 3.significantly improve cycle efficiency. |
The economizer can absorb the heat of high temperature flue gas,reduce the exhaust temperature,save energy,and improve the efficiency of boiler.
Non-standard size please provide these parameter
Boiler economizer(gas liquid heat exchanger)design | ||||
Flue gas inlet(temp.) | Flue gas outlet(temp.) | Liquid inlet(temp.) | Liquid outlet(temp.) | Flue gas flow |
ºC | ºC | ºC | ºC | m3/h |
FAQ
A: The brand name of this product is HD Boiler.
A: The model number of this product is Boiler economizer.
A: This product is made in China.
A: This product is certified by ASME, ISO9001:2015, and ISOEN3834.
A: The minimum order quantity for this product is 3 tons.
A: Yes, the price for this product is negotiable.
A: This product is packaged in iron frames.
A: The delivery time for this product depends on the quantity ordered.
A: The payment terms for this product are 30% after contract and balance 70% before shipment, or 100% L/C at sight.
A: The supply ability for this product is 100 tons per month.