Send Message
Home ProductsBoiler Economizer

Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler

Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler

  • Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler
  • Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler
  • Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler
Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler
Product Details:
Place of Origin: China
Brand Name: HD BOILER
Certification: ISO9001 , SGS , TUV , ASME , EN
Model Number: Economizer
Payment & Shipping Terms:
Minimum Order Quantity: 1 Set / Sets 10tons
Price: Negotiable
Packaging Details: Seaworthy Packing
Delivery Time: 30 days
Payment Terms: Western Union, L/C, T/T
Supply Ability: 500 Tons per month
Contact Now
Detailed Product Description
Material: Stainless Steel Usage: Power Plant/CFB Boiler
Type: Natural Circulation Structure: Hot / Water Tube
Output: Hot Water/Steam Fuel: Coal/Gas/Oil-fired, Water Heat
High Light:

power plant economizer

,

economizer for boiler

Spiral type H type fin tubes boiler economizer ASME For circulating fluifized bed boiler

 

Introduction

 

Exhaust heat loss is the largest of the heat loss of the power plant boiler, usually 5% to 8%, accounting for 80% of the total heat loss of the boiler or higher.
The main factors that affect the heat loss of the exhaust gas are the boiler exhaust temperature. Under normal circumstances, the exhaust heat temperature increases by 10 ℃ and the exhaust heat loss increases by 0.6% ~ 1.0%.
China's current thermal power units in the boiler exhaust gas temperature is generally around 125 ~ 150 ℃, the actual smoke temperature is higher than the design value is ubiquitous phenomenon.

 

Low temperature economizer

 

"Low temperature economizer", can greatly reduce the flue gas temperature, so that the flue gas temperature be reduced lower 40 ~ 50 ℃ or more.
The energy absorbed by the "low temperature economizer" can be used to heat the condensate or to increase the temperature of the combustion air by heating the air through the heater.
Power plant boiler using "low temperature economizer", can save 1 ~ 4g / kWh, unit efficiency increased by 0.2 to 1.2%. "Low temperature economizer" in the full recovery and utilization of exhaust heat at the same time, but also to achieve the best desulfurization efficiency of smoke temperature, greatly reducing the desulfurization tower to reduce the smoke and water spray cooling water consumption.
Under normal circumstances, it takes 1 ~3 years for power plant 1 to recover the investment in "low temperature economizer" and its system equipment , that is to say, the economic benefits are enormous.

 

Function

 

(1) The economizer is a steam generation system as like a boiler. when the exhaust gas discharge from the engine cylinder through the exhaust valve it goes to the boiler for generate steam by heating of water.

 

(2) After those gas it goes through the economizer the remaining exhaust gas temperature is heated the water in economiser. it help to generate steam, and it is improving the efficiency and save the fuel consumption

 

(3) An economizer uses the waste heat from the boiler exhaust, that would otherwise be lost to atmosphere to (in most cases) preheat the feed water into the boiler.This improves the boiler efficiency and reduces fuel costs.

 

*Note:HD BOILER can bespoke special type of economizer according to customer's requirement.

 

Technical specifications:

Material Structure
Consists of a serious of spiral fin tubes, the headers of inlet and outlet, bend, frame and other auxiliaries.
Structure Arrangement
In line / staggered arrangement.

 

 

Manufacturing and acceptance criteria:

 

· JB/T6512 "boiler with a high-frequency resistance welding spiral fin tube manufacturing technology conditions"
· HG/T3181 "high-frequency resistance welding spiral fin tube"
· JB/T6511 "spiral finned tube test technical conditions."
· JB1611 "boiler tube mane box assembly conditions"
· JB/T1612 "boiler pressurufacturing conditions."
· JB16I3 "boiler pressure parts welding conditions."

 

 

Spiral Type H Type Fin Tubes Boiler Economizer ASME For Circulating Fluifized Bed Boiler 0

 

Company Introduction

HD Boiler offers a best in class facility,including:

  • Fabrication area of 200,000 square meters
  • 150 Engineers
  • 600 Coded welders
  • 60 Licensed Inspectors (including NDT level-lll instructors)
  • Grade-ALicenses for Design and Manufacture boiler (issued by the State Administration of Quality Supervision and Inspection)
  • ISO 90001:2008 Quality System
  • ASME Certificate of Utility Boiler
  • ASMES’ , ‘U’ and NB stamp authorization

 

 

Contact Details
Zhangjiagang HuaDong Boiler Co., Ltd.

Contact Person: Miss. Sandy Chen

Fax: 86- 512-58774453

Send your inquiry directly to us (0 / 3000)

Contact

Address: Address: N0.1, Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China

Factory Address:Address: N0.1, Dongli Road, Donglai, Zhangjiagang City, Jiangsu Province, China