logo
Quality ASME Steel Fin Tube Economizer Boiler Parts For Once - Through Boilers factory
<
Quality ASME Steel Fin Tube Economizer Boiler Parts For Once - Through Boilers factory
Quality ASME Steel Fin Tube Economizer Boiler Parts For Once - Through Boilers factory
>

ASME Steel Fin Tube Economizer Boiler Parts For Once - Through Boilers

Brand Name: HD Boiler
Model Number: Boiler Economizer
Place of Origin: China
Certification: ISO9001, SGS, ASME, EN
Minimum Order Quantity: 1 Set

Product Details


Type: Economizer,Finned Tube Fuels: Coal
Circulation: Once-Through Standard: ASME
Highlight

power plant economizer

,

economizer for boiler

Product Description

 

Steel Boiler Economizer Boiler Spare parts Fin Tube Economizer

 

 
Summary
 
There are three stages from the feed water in the boiler heated into superheated steam:feed water preheating, evaporation, and superheating. The three stages are finished on three different heating surfaces. The boiler steam and water circuit are composed of the three different heating surfaces as well as their connecting pipes. Boiler economizers are one of them, and it is right the equipment to preheat the feed water. Thus, it is the heating surface with the lowest temperature for boiler working fluid in the boiler steam and water circuit. The working fluid passing through this equipment is monophasic water(non-boiling economizer).
 
Functions
 We can summerize the functions of economizers as below:
1. fuel saving: the economizers are placed at the rear part of boilers. This way can decrease the smoke and gas temperatures, thus to save fuels.
2.improve the working conditions of steam drums: due to economizers, the feed water temperature is increased when entering the steam drum. It reduces the temperature difference between the feed water and steam drum wall as well as steam drum thermal stress, so that it improve the working conditions of steam drums and increase the service life.
3.reduce the boiler manufacturing cost: for the feed water is heated in the boiler economizers. The use of low temperature spare parts as boiler economizers to replace some of high-priced high temperature water wall panels reduces the cost to manufacture boilers.
ASME Steel Fin Tube Economizer Boiler Parts For Once - Through Boilers 0
 
Working principle
 
Boiler economizer is kind of heat exchanger to heat the feed water using the flue gas heat. The flue gas coming from the tube outside is up and down cross-flow scrubbing the tube bundle, passing the heat to the tube wall. The water is flowing from bottom to top, and absorts the heat from the tube wall, and its temperature is getting high. This way not only can countercurrent heat transfer to save metal consumption, but also is good for water/steam to flow and exhaust as well as decreasing corrusion. One more, this way works well for dust cleaning.
 
Types
If according to heating extension of the working fluid, economizers can be divided into non-boiling and boiling types.
Most of medium-presssure boilers use boiling type economizers. This is because the latent heat of vaporization of water in medium-pressure boilers is high, and the heat of the heated water is smal. Thus it is necessary to send some water to be vaporized in boiler economizer so as to prevent unstable combusion in funaces and prevent increased consumption of metal in the heating surfaces as superheaters caused by too low outlet flue gas temperature. In addition, it can help to play the role of economizers.
Superhigh pressure boilers mostly use non-boiling type economizers. This is because when the pressure is higher, the latent heat of vaporization is decreased, while heat of the heated water is getting more, so it is necessary to send some water to be heated in water wall panels so as to prevent the slagging on the heating surfaces of the furnace outlets and the furnace inside caused by too high temperatures in furnaces and of outlet flue gas. So usually superhigh pressure boilers use non-boiling type economizers.
The main factor to consider which type of economizers is boiler's parameters. When the boiler parameters differ, the ratio of heat absorption needed in three stages to heat the working fluid make differences. So the corresponding arrangements of three heating surfaces need to change, too. To large units with high parameters, their evaporative heat absorption is less, while the heat absorption of water by heating, the heat absorption of steam by superheating, the heat absorption by reheating are quite big. Thus, non-boiling type economizers are the main type for superhigh pressure unit boilers.
 
Specifications

 
Description Boiler economizer
Material Alloy steel, Carbon steel, SA210C ,SA213T22, etc.
Material standard ASTM, EN or ISO etc.
Dimension Customization
Weight

Min: 10 ton
Max.:1000 ton

Smelting Process: EF+LF + VD
Process Material→Ingot → Hot/Cold-Rolling→ Heat treatment (Normalizing+ tempering) → Inspection →rough machining→UT →2nd Heat treatment →finishing machining →Inspection
UT standard ASTM A388 or EN10228, etc

 
Quality Control
 
1. Impact test and Strength calculation report with applied materials information.
2. 100%NDT(non-destructive inspection) report of steel plate, tube and electrode
3. X-ray, γ-ray and liquid penetrant test inspection report (welding seam): to ensure the quality of the entire boiler
4. Hydraulic test report: ensure the standard working pressure and safety

Product Highlights

Steel Boiler Economizer Boiler Spare parts Fin Tube Economizer Summary There are three stages from the feed water in the boiler heated into superheated steam:feed water preheating, evaporation, and superheating. The three stages are finished on three different heating surfaces. The boiler steam and ...

Related Products
Quality High Pressure Power Boiler Heating Surface Membrane Wall Argon Arc Welding For Biomass Boiler factory

High Pressure Power Boiler Heating Surface Membrane Wall Argon Arc Welding For Biomass Boiler

High Pressure Power Boiler Heating Surface Membrane Wall Argon Arc Welding For Biomass Boiler Product Introduction Water wall panels with pins usually laid vertically on the inner wall of the furnace wall, it is mainly used to absorb the radiant heat emitted by the flame and high-temperature flue gas in the furnace.It is the main type of evaporating heating surface of all kinds of modern boilers and the basic component of boiler water circulation loop.Because of both cooling

Quality High Frequency Welding H Fin Tube Economizer For Power Plant Boiler ASME factory

High Frequency Welding H Fin Tube Economizer For Power Plant Boiler ASME

High Frequency Welding H Fin Tube Economizer For Power Plant Boiler ASME Product Description The boiler economizer is a device used to recover waste heat in industrial boilers, usually located at the tail of the flue of the boiler, which increases the feed water temperature and reduces fuel consumption by absorbing the heat of the flue gas, so as to achieve the effect of energy saving and emission reduction. But at the same time, as an environmental protection equipment, the

Quality Carbon Steel SA192 Superheater Coil Argon Arc Welding 100% PT factory

Carbon Steel SA192 Superheater Coil Argon Arc Welding 100% PT

Product Description: A boiler superheater is an essential component in a boiler system, responsible for increasing the temperature of steam produced by the boiler. One of the key products in this category is the Superheater Coil, designed to enhance the efficiency and performance of boiler systems. This particular superheater is suitable for various fuels, including coal, oil, and biomass, making it versatile and adaptable to different energy sources. The Superheater Coil

Quality Boiler Industrial SA210A1 Steel Boiler Economizer Heat Exchange Part ASME Certification factory

Boiler Industrial SA210A1 Steel Boiler Economizer Heat Exchange Part ASME Certification

Boiler Industrial SA210A1 Steel Boiler Economizer Heat Exchange Part ASME Certification Introduction The H-shaped finned tube is also known as the H-shaped fin tube, also known as the butterfly fin tube. It is to weld symmetrically two pieces of steel with an arc in the middle to form fins (ribs or butterflies), the frontal shape of which resembles the letter "H", so it is called the H-shaped finned tube. The two fins of the H-shaped fin tube are rectangular and approximately

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.